(Subsystem 133) |  |
- 5
- MESSAGE
The PID has not been created. - CAUSE
The specific process no longer exists in the system.
The process has been specified by the Measurement Interface (MI)
user through the SUBCLASS_ARRAY parameter in the procedure ENABLE_MEASUREMENTS. - ACTION
Retry with the correct process ID.
- 10
- MESSAGE
The group PARM is greater than MAX_GROUP_IN_CLASS for requested class. - CAUSE
The user of procedures which require a group value entered
an index value for the group which is outside the range for groups
within a performance class. - ACTION
Remove faulty value and try again.
- 15
- MESSAGE
Too many user or program names given in an ENABLE_MEASUREMENT call; ENABLE_MEASUREMENTS does continue, however. - CAUSE
The user of the ENABLE_MEASUREMENT procedure has
requested more than 10 program names and/or 10 user names. - ACTION
Reduce the number of names to 10 (10 programs and/or
10 user names) and try again.
- 25
- MESSAGE
The total subclasses were zero; condition not acceptable. - CAUSE
A negative or zero value for the parameter for TOT_SUBCLASSER
for ENABLE_MEASUREMENT and/or DISABLE_MEASUREMENT procedures. - ACTION
Correct the value and retry.
- 35
- MESSAGE
The measurement interface PID list is full. - CAUSE
The user of ENABLE_MEASUREMENT has requested more
than 2700 processes to monitor. - ACTION
Reduce the number of processes requested and try
again.
- 50
- MESSAGE
The user buffer is not large enough to hold all requested counters. - CAUSE
The user of GET_MEASUREMENTS has passed a buffer to
receive performance data which is too small. - ACTION
Increase buffer size and try again.
- 65
- MESSAGE
The counter table has no more entries, so all groups requested got enabled. - CAUSE
Major problem with the MEASUREMENT INTERFACE data
structure whereby there was a problem getting enough memory to create
the counter array. - ACTION
Scale back on the number of items being measured
or expand memory.
- 70
- MESSAGE
The requested class has an index value less than zero or greater than the current total number of classes. - CAUSE
The requested class in ENABLE_MEASUREMENTS, GET_MEASUREMENTS,
and/or DISABLE_MEASUREMENTS is not within the range of 1 to 3. - ACTION
Correct the class value and try again.
- 90
- MESSAGE
A new subclass is requested, but the LOOKUP TABLE is full. - CAUSE
A user has specified more LDEVs than the IO LOOKUP TABLE
can accommodate in the call to ENABLE_MEASUREMENTS. - ACTION
Be more selective on the number of I/O devices.
Adjust the number of LDEVs and try again. See limits in the MPE
XL Measurement Interface User's Guide.
- 100
- MESSAGE
ENABLE of measurement subclass failed. - CAUSE
A user has tried to enable performance measurements through
the procedure ENABLE_MEASUREMENTS, but the number of MI users exceeds
the limit of 25. - ACTION
Wait until an MI user quits and retry.
- 110
- MESSAGE
No measurement ID entry in the MI_ID TABLE. - CAUSE
A user has called GET_MEASUREMENTS or DISABLE_MEASUREMENTS
without first enabling measurements through the procedure ENABLE_MEASUREMENTS. - ACTION
Check to be sure that you first call ENABLE_MEASUREMENTS.
- 130
- MESSAGE
The current class has been ENABLED too many times without intervening DISABLES. - CAUSE
Either 1) a second enable for global class, 2) more
ID class enables than total number of device classes or more LDEVs
than exist in given device class, or 3) a change in groups selected
with new enables for new process in process class. - ACTION
Correct misunderstanding in using ENABLE MEASUREMENTS.
See the MPE XL Measurement Interface User's Guide for
more information on using the procedure ENABLE_MEASUREMENTS.
- 140
- MESSAGE
The number of counters do not match the known number of object classes. - CAUSE
User called CONVERT_TO_STD_OBJCL procedure with group
whose group header shows a number of counters to be not 10, 33,
or 501. - ACTION
Check to be sure group is an object class group.
Modify input and try again.
- 150
- MESSAGE
The group index does not belong to an object class group. - CAUSE
User called CONVERT_TO_STD_OBJCL procedure with a
group that is not recognized as an object class group for the particular
class. - ACTION
Check to be sure the group is an object class group.
Modify input and try again.
- 160
- MESSAGE
LDEVS in the array are not all of the same device type. - CAUSE
User called ENABLE_MEASUREMENT with an array of LDEVs
that are not of the same device class, or user called DISABLE_MEASUREMENTS
with an array of LDEVs that are not of the same device class. - ACTION
Correct LDEVs in the array to be of the same device
class and retry.
- 170
- MESSAGE
Failed to obtain lock for the MEAS_KSO_TABLE. - CAUSE
Major problem with MEASUREMENT INTERFACE data structure
or control block lock code of the operating system. - ACTION
Call your Hewlett-Packard Representative.
- 180
- MESSAGE
Failed to obtain lock for the PROCESS LOOKUP SUBCLS TABLE. - CAUSE
Major problem with MEASUREMENT INTERFACE data structure,
or control block lock code of the operating system. - ACTION
Call your Hewlett-Packard Representative.
- 190
- MESSAGE
Failed to obtain lock for the NAME POINTER LIST TABLE. - CAUSE
Major problem with MEASUREMENT INTERFACE data structure,
or TABLE MANAGEMENT control block lock code of the operating system. - ACTION
Call your Hewlett-Packard Representative.
- 200
- MESSAGE
Failed to obtain lock for the MI_ID TABLE. - CAUSE
Major problem with MEASUREMENT INTERFACE data structure,
or Table Management control block lock code of the operating system. - ACTION
Call your Hewlett-Packard Representative.
- 210
- MESSAGE
Failed to obtain lock for the USER_LIST TABLE. - CAUSE
Major problem with MEASUREMENT INTERFACE data structure
or TABLE MANAGEMENT control block lock code of the operating system. - ACTION
Call your Hewlett-Packard Representative.
- 220
- MESSAGE
Failed to obtain lock for PROG_LIST TABLE. - CAUSE
Major problem with MEASUREMENT INTERFACE data structure
or TABLE MANAGEMENT control block lock code of the operating system. - ACTION
Call your Hewlett-Packard Representative.
|