In order to run ACC Version B.03.30.00 with Z7340A Serial ACC cards on HP Superdome servers, patch PHNE_24871(s700_800 11.11 3.30.00 ACC Base Software Product Patch) or its superseding patch must be installed. This patch also fixes ACC code so that "ioscan -fC acc" output displays the card number and the card description (on all supported servers).

The patch, along with additional information, can be downloaded from http://itrc.hp.com/. The patch is also available from ftp://hpatlse.atl.hp.com/hp-ux_patches/s700_800/11.X/.

Defect Fixes in Patch PHNE_24871

This patch for ACC B.03.30.00 fixes the following 2 defects for Superdome customers.

  • JAGad87791

    Symptom: ACC card description in "ioscan -fC acc" output needs to be more informative.

    Defect/Fix: The code has been changed so that "ioscan -fC acc" output displays the card number and the card description.

  • JAGad83768:

    Symptom: zmasterd cold start fails on Superdome

    When running ACC Version B.03.30.00 with Z7340A PCI Serial ACC cards on Superdome, zmasterd cold start fails. The cards do not start up and zmon provides an error message stating that there is no ACC card in the slot configured.

    This problem results from an extra zero being added to the I/O path on Superdome systems. For example, if an N-class system has an I/O path of 16/4/1/0, on a Superdome system, the same path would be "16/4/1/0/0". The function nacc1_get_interface_info() looks at the path entries starting with the rightmost element and working left. On a superdome system, this yields a bus address of 4:1 and a slot address of 0 instead of a bus address of 16:4 and slot address 1.

    Defect/Fix: The address parsing has been changed to start with the leftmost element and then work right for PCI bus. This should result in consistent bus and slot addresses regardless of the target system supporting PCI bus.

Defect Fixes From Release ACC B.03.30.00

  • JAGad16980

    Symptoms: pdisplay runc on ports 2 and 7 of the 2/8-port cards does not work and outputs the following error:

    Error: Port 7 exceeds the maximum allowed for the card type.

    Defect/Fix: Whenever you try to use the runc command to configure the last port of any 2-port or 8-port ACC card, the command fails with an error. This defect was caused by a logic error in the port validation code. This defect has been corrected.

  • JAGad13781

    Symptoms: zmasterd cold startup or x25init failure indicating insufficient HP-UX memory for the operation.Defect/Fix: The root cause for these failures was the code holding a spinlock when calling MALLOC with wait. If MALLOC needed to sleep in this case, it would return a NULL pointer which normally indicates no memory available. The fix is to unlock the spinlock before calling the MALLOC macro.

  • JAGad09926

    Symptoms: x25init fails with the following message:

    [x25stop] X.25 interface zx25m0p2 has been stopped
    ixetune: IXE_SNREG ioctl failed: Invalid argument
    Too many IXE lines configured in /etc/netconf

    Defect/Fix: The fix is in the application using X.25. If an application is using the X.25 subsystem with ACC, and if the "zmasterd stop" or "zmasterd kill" command is issued, a "x25stop -K" command must be issued. The "x25stop -K" command should be issued after doing the zmasterd stop/kill command. This is necessary because the zmasterd stop/kill command deallocates the ZCOM data structures and there is no way the X.25 subsystem would know that the data structures have been deleted. If the "x25stop" command is not given, then all successive "x25init" commands may give error messages stating that the "x25tune" command failed.

  • JAGad13782

    Symptoms: Multiple connections over ACC/X25 are made. After 5 days of intensive stress on the machine it needs to be rebooted because of a memory leak in the 512 bucket. The problem can be reproduced on all possible hw systems running HPUX 11.00.

    Defect/Fix: A code segment does an exit before freeing a buffer. The fix is to assign the buffer to the free buffer area before exiting.

  • JAGad14557

    Symptoms: The defect occurs when the system is under extreme load and there is large amounts of queued data that has not yet been transferred to the card.

    Defect/Fix: Under these conditions, if a call is cleared and then immediately reestablished, the data for the prior call can be transmitted on the new call. In other words, the data for the previously established VC can be sent on the newly established VC on the same ZLU. The changes are to flush the physical driver's high and low priority transmit queues for the VC whenever a inbound or outbound clear request is received.

  • JAGad16213

    Symptoms: Data page fault with PVCs in streams_put on inbound reset indication.

    Stack trace is:

    streams_put+0x2c
    N2Z_F_reset_ind+0x90
    N2z_iev_reset_ind+0x138
    N2z_ReadEvent_Recvd+0x1d94
    Zc_putq+0x60
    Zc_addq+0x1b8
    zksend+0x264
    Zx_Send_appl_status+0x2ec
    Zx_proc_VC_event+0x1498
    Zx_proc_unsol_event+0x2390
    zx25_event_handler+0x4b4
    Zc_putq+0x60
    nacc0_receive_data+0x194
    nacc0_pass_rxdata+0x88
    nacc0_complete_req+0x480c
    nacc0_end_io+0x280
    nacc0_isr+0x898

    Defect/Fix: After a PVC detach occurred (which causes the stream to be closed), an inbound request queued on the read side server was then running and passing the request upwards on a now invalid stream. This resulted in the panic. The fix is to clear the read size "q_ptr" field during the PVC detach processing which prevents any request pending on the read side from being passed upwards.

  • JAGab66302

    Symptoms: This is an enhancement to zmasterd to accept .answ file on cold start.

    Defect/Fix: zmasterd now accepts a .answ file on cold start and runs ttgen itself, as well as being able to cold start from a .tmem file. This involves making changes in zmon such that it can accept a .answ file for cold start, and run ttgen internally.

  • JAGad00600

    Symptoms: "zmasterd deact znode" does not kill the znode daemon.

    Defect/Fix: "zmasterd deact znode" left znode still running, whereas "zmasterd deact zmlog" removes zmlog from the run state.

    The problem was occurring because the znode daemon was ignoring the SIGTERM signal. Code has been modified so that the znode daemon no longer ignores the SIGTERM signal.

  • JAGad02457

    Symptoms: The interface tunable tsize parameter for the E1/T1 cards and Z7340A 8-port PCI has inadequate editing in ttgen and checking in the firmware, and an incorrect value such as 1 can cause a firmware failure.

    Defect/Fix: The minimum allowable value is 8 bytes. This would allow the header only, with no timers. The actual value must be a multiple of 8 bytes. Each timer entry occupies 8 bytes, in addition to the header. Interface tunable "tsize" has been fixed to be multiple of 8; and minimum 8.

  • JAGad04280

    Symptoms: DSC card control (startup/disable) does not work.

    Defect/Fix: While doing DSC card-config tests (zconfig), it was found that the system shuts down a card even when a DSC card-startup or card-disable request is issued.

    The reason for the above problem is that some "break" statements were missing in the switch statement in dsc_card() function of LDM code. It also misses out the setting of "irr.reason" to indicate different reasons for card disable or halt.

  • JAGad21743

    Symptoms: During high load activity on the Z7200A OR Z7400A ACC cards, such as X.25 call establishment and clearing on all port, the port may be unable to accept further transmit requests. The affected port is not usable until the ACC card is restarted.

    In the case of X.25 call establishment, the user application may encounter the error return ENOSPC.

    Defect/Fix: The transmit processing for the affected port was stalled, because the firmware was in an inconsistent state. Two problems in the low level state processing of the frame protocol have been identified and removed. A workaround has been implemented for an inconsistent state where the transmit timer was not running, but the transmitter was active. Additional protection has also been added to interrupt critical state processing.

  • JAGad25064

    Symptoms: ACC 8 port PCI was sending 1 byte data packet.

    Defect/Fix: The default SAM values for N2Z_OUTB_BUFFER_SZ and N2Z_MAX_ZSTRBUF_PGS were incorrect and have been modified.