JAGad21743
Symptoms: During
high load activity on the Z7200A OR Z7400A ACC cards, such as X.25 call
establishment and clearing on all port, the port may be unable to
accept further transmit requests. The affected port is not usable
until the ACC card is restarted.
In the case of X.25 call establishment, the user application
may encounter the error return ENOSPC.
Defect/Fix: The transmit
processing for the affected port was stalled, because the firmware
was in an inconsistent state. Two problems in the low level state
processing of the frame protocol have been identified and removed.
A workaround has been implemented for an inconsistent state where
the transmit timer was not running, but the transmitter was active.
Additional protection has also been added to interrupt critical state
processing.