The format of the Port Definition Parameters section of the
TTGEN Configuration File is as follows, with the second example
representing Z7300A. Note that the parameters that must reflect
your configuration are enclosed in < >. Suggested
values for these parameters are given below. All other parameters
should be used as shown.
Port-Definition Port <mux>:<port> <port mode> <baud> <clock source> SDLC X1 NRZ Port <mux>:<port> <port mode> <clock source> <frame> <encode>
|
Each Mux port that is used by the X.25/9000 Streams product
must be configured in the Port-Definition section
of the TTGEN Configuration File. The parameters to be configured
are given in the ACC Mux Worksheet.
Port |
 |
Port being configured. The valid port numbers are 0 to 7 (0-1
for Z7350A, 0-3 for Z7300A and Z7330A or Z7330B).
Port Mode - 8-Port/2-Port Interface Cards |
 |
The valid port mode values are:
LBACK (Tristate (Loopback))
V36 (V.36)*
* Valid on 2-channel NIO and 8-channel PCI ACC cards only
The Tristate or Loopback
mode is used to put a mux port into "tri-state" mode,
which is typically only used with Dual Interface Configurations. Refer
to the ACC Installation and Configuration Guide for
more information on Dual Interface Configurations and to Appendix F “ACC Service Guard Configuration
Notes” for more information about use with Service Guard.
Port Mode - 4-Port Interface Cards |
 |
The valid Z7300A port mode values are:
LBACK (Tristate (Loopback))
Baud - 8-Port/2-Port Interface Cards Only |
 |
The valid baud rate values for these ACC interface cards are
150, 300, 600, 1200, 2400, 4800, 9600, 14400, 19200, 38400, 48000,
57600, 64000, and 76800. For the Z7400A 8-channel ACC (EISA) card
a baud rate of 128,000 is also valid.
For the Z7340A 8-channel and Z7350A 2-channel ACC cards, the following
additional baud rates are available:
| 56000 |
| 128000 |
| 153600 |
| 192000 |
| 256000 |
| 307200 |
| 384000 |
| 512000 |
| 768000 |
| 1024000 |
| 1228800 |
| 1536000 |
| 1544000 |
| 2048000 |
 |
 |  |
 |
 | NOTE: The sum of the baud rates for both ports on a 2-Channel
card must not exceed 2,112,000.Baud is not a valid parameter for Z7300A, Z7330A, or
Z7330B 4-Port T1/E1 interface cards. |
 |
 |  |
 |
Frame Mode - Z7300A 4-Port T1/E1 Interface Only |
 |
Valid frame modes for Z7300A are as follows:
Encode Mode - Z7300A 4-Port T1/E1 Interface Only |
 |
Valid encode modes for Z7300A are as follows:
AMI (Not currently supported)