Both server blade and Power Supply cooling are shown in Figure 3-6 “Cooling Airflow into the Blade Server” and addressed in this section.

  • The CompactPCI server blades in the main chamber are cooled by the fan tray.

    NOTE: The N+1 fan tray assembly is an integral part of the blade server chassis and cannot be removed or replaced in the field.
  • Each PSU is cooled independently by its own set of 4 fans.

Figure 3-6 Cooling Airflow into the Blade Server

Cooling Airflow into the Blade Server

Because of the high velocity positive pressure airflow, the mechanical integrity of the system must be maintained at all times to ensure proper cooling:

  • All slot blockers must remain in place over unused slots.

  • Blade installation must be completed within three minutes from removal of the slot blocker.

Any deviation from these requirements may result in the management blade shutting down the entire system.