blade server power-up consists of
providing power to the management blade first, then the remainder
of the server blades begin their power-up procedures.
Chassis
and Management Blade Power-Up |
 |
Connect the power cords between
the blade server power supplies and the DC power source. The blade
server chassis will immediately begin to power-up and the console
will display power-up self test data.
Look for the slot F10 status LED. Status LEDs are located
in a vertical panel on the cooling fan assembly cover. When chassis
power-up has been successfully accomplished, the management blade
status LED will be green. You can now log on to the management blade
to perform management blade and bp2200 (PA) server blade MP configuration.
Refer to Chapter 5 “hp Carrier Grade Server bh3710 Server Blade
Installation Information ”for
network configuration procedures.
bp2200
Server Blade Power-Up |
 |
When
bp2200 server blade configuration is complete, exit the management
blade configuration menu and select, 3. exit to LINUX Shell. The console will begin to display boot/self-test
data and, upon successful completion of boot and self-test procedures,
the HP-UX login prompt will be displayed. When server blade power-up
has been successfully completed, the status LED for slot F10 will
be green.
The bp2200 server blade powers up and, when the green LED
beside the blade slot is illuminated, it is ready for configuration.